contact@cilico.com
  • Android 11
  • RFID
  • Octa-core 2.0GHz
  • 5.72”inch IPS
  • 4GB RAM+64GB ROM
  • 4G/Dual-band Wi-Fi
  • IP67
  • 1D/2D barcode scanning
Highly integrated design for widely industry applications
Barcode/RFID/PSAM/NFC/Camera

Comfortable grip

not easily fatigued


Ergonomic handle, anti-slip and anti-fatigue design

It is not easy to get tired after being used for a long time

screens, papers and wristbands

12200mAh Large 

Capacity Battery


Power is abundant, working worry-free

Removable handle battery, convenient and fast


  • Professional barcode scanning

  • high speed and accuracy



With international professional scan engine

Quickly read 1D/2D/distorted/defaced/old barcode

Keep your work productive at all times


IP67 dustproof 

and waterproof


1.5m anti-drop, meet IEC sealing standard

360 ° all-round, super protection, reliable and durable

It can meet the outdoor use needs of rain, snow, fog and other harsh weather


Powerful ultra-long distance

easy batch reading


Industry leading Impinj RFID chips

Batch reading RFID tag up to 15-30 meters 


Applications
C80R series mobile computers are widely deployed in logistics, transport, healthcare, retail, manufacturing, warehouse management, attendance management etc.
  • Healthcare Healthcare
  • Logistics Logistics
  • Manufacturing Manufacturing
  • Warehouse Warehouse
  • Ticketing Ticketing
  • Retail Retail
Specifications
  • Basic Parameters
    Size 169X76.8 X 26mm
    Weight 660g(including battery)
    Display 5.72inch 18:9 HD+(1440*720)
    Touch panel Gorillaglass, plated with anti-fingerprint film, supports wet hand operation
    Backlight LED Backlit
    POWER Removable terminal battery: 4600mAh, 3.8V
    Removable handgrip battery: 6000mAh, 3.8V
    Working time: more than 8 hours, Standby time:300 hours
    SIM SIM+TF: nanosim+nanosim/TFCard
    USB port Type-c, Support OTG
    Network connections 4G/3G/2G,Wi-F,GPRS
    Notification Tone; LED indicator; Vibration
    Keyboard On-screen keypad, 3 virtual buttons: Backs Home、Menu
    Audio A microphone, speaker, receiver
    Button Power key, Two scan keys, Volume +- key, custom key
    Power adapter Input: 100-240V,50/60HZ 300Ma, Output: 5V,2A
    Working environment
    Operating temperature -20℃ to 55℃
    Humidity 5% to 95% (Non-condensation)
    Drop specification Withstand multiple drops from 4.9 ft / 1.5m to concrete floor in operating temperature range
    Roll Specification Can Withstand 200 times 1.6 ft/0.5 m rolling impact; meets or exceeds IEC
    Vibration Random(10 Hz-30KHz);60 minutes per shaft
    Electrostatic protection +/- 10kv air discharge +/-6kv contact discharge
    Sealing Host IP67
    ESD +/-10kv air discharge, +/-6kv contact discharge
    Wireless Communication
    WWAN Asia + Europeband: GSM:Band2/3/5/8 WCDMA:Band 1/2/5/8 TD-SCDMA:
    Band 34/39 CDMA:Band BCO TDD-LTE:Band 34/38/39/40/41 FDD-LTE:
    Band 1/3/5/7/8/20
    American band:
    GSM:Band2/3/5/8
    WCDMA:Band 1/2/4/5 CDMA:Band BCO
    TDD-LTE:Band 40/41
    FDD-LTE:Band B1/2/4/5/7/28A/28B
    WIFI 2.4GHz&5GHz Protocol:802.11 a/b/g/n/ac/r/e/i
    Fast Roaming
    navigation Beidoux Glonass、GPS、GalileOxQZSS
    Version Bluetooth 5.0
    FAQ
    1.No reaction when putting the NFC card close to the device.  Step 1: Please make sure that the card-reading function is opened;
    Step 2: Check whether the frequency of the card matches well with the protocol; ( Currently, it only supports high-frequency card including MF0,MF1,15693,CPU).
    2.The requirement of RFID products with UHF to environment. Metal and liquid (water) material have a strong interference to the UHF signals ( the closer to the tag antenna, the stronger interference of the signal); It is able to adopt anti-metal tag in the metal environment, however, it still remains hard to solve problems in liquid environment.
    3.There is light emitting from the scanning head but fail to scan. If it fails to scan suddenly in use, the same setting of the scanning head and the barcode to be scanned may possibly result in it. If you change the setting of the scanning head unintentionally, you are supposed to scan other types of barcodes and send the result feedback to Cilico.
    4.The left and right scanning button fail to work or only one side button could work Step 1: Please make sure that the left and right scanning options are opened;
    Step 2: Close the scanning type APP;
    Step 3: Try to scan with system scanning option; if it works, then the device is working properly.
    5.What am I supposed to do when the reflash process is interrupted? Step 1: Disconnect USB;
    Step 2: Take out the battery and install the battery agian;
    Step 3: Repeat reflash process.
    6.The device fails to charge. Step 1: Change the battery or charge with the USB cable  and try to start up;
    Step2: If it still fails to charge to start up after changing the battery, it is possible that the battery is over discharged. Please keep the charging connection with USB cable, then take out the battery and instsall again, activating the battery by repeating 3-4 times. Try to start up after charging for 30 minutes. 
    7.Why does the device enter factory mode when it is turned on. The possible cause is that the volume - key is pressed when the phone is started up. You can press the Volume - key or select Restart and press the power button to restart the phone.
    8.What is the best distance for bar code scanning The optimal scanning distance depends on the size of the bar code. The optimal scanning distance of the large bar code will become longer, while the optimal scanning distance of the small bar code will become smaller. Generally, the optimal scanning distance is between 10-15cm.
    9.How do I access the Developer options In Settings/About Phone, click on the Build number 5 times to exit About Phone and Click on system-Advanced in order to see the developer options.
    10.The kind of protocol used by UHF International standard 18000-6C protocol used
    11.How do I view the device version Enter from device, click Settings - About Phone - Build number
    12.How do I restore the device to factory Settings Device interface click Settings - System - Reset Options - Erase all data(factory reset)
    13.Why can't the device recognize the phone card and access the Internet by phone Step 1:Ensure that the mobile phone card is installed in the SIM card slot
    Step 2:Ensure that the data traffic switch Settings - Traffic Usage - Carrier-data switch are enabled
  • Performance Parameter
    CPU Octa-core 2.0GHz
    OS Android 13
    Memory 4GB RAM/ 64GB ROM
    Data Collection
    Bar code Engine Zebra/ Honeywell/Newland
    1D Symbologies EAN-13, EAN-8, UPC-A, UPC-E, Code 128, Code 39,
    Codabar, UCC/EAN-128, RSS, ITF, ITF14, ITF6, ISSN, ISBN,
    Standard 25, Matrix 25,Industrial 25, Plessey, MSI Plessey,
    Code 11, Code 93, etc.
    2D Symbologies PDF417, Micro PDF417, QR Code, Micro QR, DataMatrix,
    AZTEC, Maxicode, Composite, etc
    Camera Front-5MP(optional)
    Rear-13MP, autofocus;
    Rear camera flash; Support flashlight mode
    Internet of things function
    NFC working band:13.56MHz Support Protocol: MifareClassic (MFI) NDEF, NfcV (15693) ,Ultraligh(MF0), IsoDep (CPU MF3) JsoDep (CPU) Read Distance:0-5cm
    RFID Workingband:CHINA: 920-925MHz; USA: 902-928MHZ;EU: 865-868MHz; Protocol: IS018000-6C/EPCC1G2 Read Distance: around 0.8m depends on thetags
    Security PSAM Supporting ISO7816 standard, supporting 2PSAM cards
    Sensors Light Sensor, distance sensor, gravity accelerometer, geomagnetic sensor, Hall Effect Sensor (Optional)
    Others
    Certification CE/CCC/FCC/GMS/AER/RoHS/IP67/TAC/UN38.3
    Standard accessories Adapter/data cable/battery/hand strap /NFC test card/UHF test label
    Optional accessories Charging cradle /charging cradle adapter/battery/tempered film
Downloads
A
L
L
Contact Us

Subscribe to our newsletter